Product categories
Clamp-Type Ultrasonic Flowmeter Special For Superfine Tube| Q3
Product description

As a clamp-on ultrasonic flowmeter, Q3 does not need to break the pipe, and does not need to change the pipeline cross-measurement structure. It only needs to be stuck outside the pipe, which reduces the instability in the measurement process and ensures the measurement accuracy.


Product Details

Product Introduction

Name: Clamp-Type Ultrasonic Flowmeter For Superfine Tube

Model: SUNCENT-Q3

Brief Description:

Q3 is a special ultrasonic flowmeter for ultra-fine tubes, which is specially designed to meet the measurement requirements of small diameters such as hoses and hard tubes. It is mainly used in semiconductor, medical, chemical production process, fine chemical production, cleaning industry and beverage industry.

As a clamp-on ultrasonic flowmeter, Q3 does not need to break the pipe, and does not need to change the pipeline cross-measurement structure. It only needs to be stuck outside the pipe, which reduces the instability in the measurement process and ensures the measurement accuracy.

The sensor does not directly contact the liquid in the pipeline, so it will not pollute the liquid in the pipeline. It is suitable for occasions with high requirements for hygiene and cleanliness, such as biopharmaceutical process, liquid flow monitoring in the production of medical equipment and semiconductor equipment.

Q3 is made of ABS material by CNC machining, with good dimensional consistency, high strength and good toughness. With the advanced time measurement technology in the world, the resolution can reach 20ps.

Product Details

Flow Range


Performance Index

Flow Range0-17000ml/min

Accuracy±2.0%

Repeatability0.8%

Pipe Sizeφ4,φ6.35,φ8,φ9.53,φ12.7

Data storageDaily, monthly and yearly Flow Totalizer

KeypadFour keys

ScreenOLED 128*64 display screen

CommunicationRS485, supports Modbus communication protocol

UnitsMetric and imperial units are available: Cubic Meters(m3), Liters(L), USA Gallons(GAL), /hour, /min. Default unit setting: m³/h

TotalizerSix-bit digit

Input and Output1. RS485 Modbus or OCT alarm output (NPN)2. 4~20mA.

Frequency output:0-4999Hz,Maximum load: 600Ω

RS485 ModBus operationModBus operation supports up to 16 sensors. The default address is #1.

Power supply24VDC

current consumptionLess than 20mA (no external load)

Cable Length2m (standard)

Envir. temp0℃-80℃32℉-176℉

Medium temp0℃-80℃32℉-176℉

Envir. humidity0~90% relative humidity,without condensation

IP rateIP65